1st, application
WRN-230D, the WRN-430D multi-spot thermometer (multi-spot thermal resistance, multi-spot thermo-element) is suitable in produces the scene existence gradient of temperature not to be remarkable, must simultaneously survey many positions or position many place surveys. As the survey temperature's sensor, usually the multi-spot thermometer and the demonstration accommodometer, the recording instrument and the electronic regulator and so on necessary use, may in the direct measurement each kind of production process from 0¡æ~1300¡æ the scope liquid, the steam and the gas medium as well as the solid surface temperature. Widely applies in the big chemical fertilizer synthetic tower, saves installments and so on storage tank.
2nd, major technique parameter
Electrical export: M27X2, NPT3/4
Hot loud time: <= 8S
Occasionally silk diameter: PHI 3
Protection rank: IP65
3rd, model and specification
Model |
Indexing number |
Temperature measurement scope ¡æ |
Temperature measurement points |
Tube protector material |
WRN-230D |
K |
0-1000 |
2-12 |
GH3030 |
0-827 |
1Ci18Ni9Ni |
WRE-230D |
E |
0-1122 |
1Ci18Ni9Ni |
WRN-430D |
K |
0-1000 |
GH3030 |
0-827 |
1Ci18Ni9Ni |
WRE-430D |
E |
0-1122 |
Ci18Ni9Ni |
1) Thermometer I level according to agreement ordering;
2) multi-spot thermometer tube protector other material quality basis agreement ordering;
3) outside the multi-spot thermometer the tube protector user should supply for oneself
4th, installment fixed form
Fixed thread
Temperature measurement points |
M |
D |
H |
h |
SW |
d |
2-6 |
M27x2 |
¡é40 |
28 |
5 |
32 |
¡é20 |
7-12 |
M33x2 |
¡é48 |
33 |
5 |
36 |
¡é34 |
Fixed flange
Temperature measurement points |
D |
D1 |
D2 |
H |
do |
d |
2-6 |
¡é105 |
¡é75 |
- |
5 |
32 |
¡é20 |
7-12 |
¡é115 |
¡é85 |
- |
5 |
36 |
¡é34 |
5th, shaping notice
1) model
2) indexing number
3) precision class
4) thermometer points
5) installs the fixed form
6) tube protector material quality
7) length or depth of penetration
Example: Multi-spot thermometer, K, 3 o'clock. L level, fixed thread M27X2, L 1 = 1200, L 2 =1500, L 3 =2000, WRN-220D3I level L 1 =1200, L 2 =1500, L 3 =2000, thread M27x2 |