WZCM, WZPM series of face thermal resistance components handled by a special wire wound, compact towel in front of the thermometer, and the general axial thermal resistance compared to face thermal resistance and prompt more accurately reflect the actual temperature of the measured end for To measure bearing temperature or other parts of the face¡£ |
|
¡ñMain technical parameters |
0 ¡æ temperature sensing element when the resistance (R100) and its resistance at 0 ¡æ R0
Dividing numberCu50£ºR0=50¡À0.050¦¸
¡¡¡¡
Cu100£ºR0=100¡À0.10¦¸
Dividing numberPt100:R0=100¡À0.12¦¸(B-Level)
Where: R0 at 0 ¡æ for the components of the resistance¡£ |
¡ñRange and tolerance (units£ºmm£© |
Name |
Temperature range¡æ |
Tolerance¡÷t¡æ |
Dividing number |
End of copper resistance |
-50-100 |
¡À(0.3+6.0¡Á10-3|t|) |
Cu50 (G)»òCu100 |
Face platinum resistance |
-150-200 |
B-level£º¡À(0.30+0.005|t|) |
Pt100 |
|
¡ñModel specification |
Model |
Dividing number |
Structure |
Temperature range¡æ |
Protection tube material |
Thermal response time |
Specifications |
PN |
Lead length external lineL £¨ mm£© |
Diameterd£¨ mm£© |
M£¨ mm£© |
WZCM-201 |
Cu50 Cu100 |
Fixed buried or threaded connection |
-50-100 |
CopperT2-Y |
£¼15 |
¦µ 6 |
M8x0 .75 |
Pressure |
500
1000
1500
2000
2500 |
WZPM-201 |
Pt100 |
-150-200 |
£¼15 |
¦µ 8.7 |
M10x1 |
WZPM-201B |
|
Note: WZPM-201B with the introduction of components WZPM-018, accuracy rating for A level¡£ |
|
¡ñMounting |
|