中文版 English
          Home  Company  Product  Quality  Sales  Contact
 
 Flow meter series
 Transmitter meter...
 Pressure Meter Series
 Temperature meter...
 Check meter series
 Display Instrument...
 Wire and cable series
 Electric heating series
 
  The working principle of...
  Zirconia Oxygen Sensor...
  Hazardous gas detection...
  Our instrument for...
  China Hi-tech instrumentation.
  Development of Xi'an ...
  Precision temperature...
  The development trend of ...
  Description of several gas...
  Use of sensor technology...
  New sensors monitor the...
 
  Jiangsu Golden Delicious Control Technology Co., Ltd.,
  TEL:0517-86867887
     0517-86867888
     0517-86867889
  FAX:0517-86891587
Join Hotline:0517-86803168
              13905232000
  Technical Support:0517-86886468
  Zip:211600
  Address:Jiangsu Province, Lake County gongyuan Road, No. 1
 You are Here > Home > Product
     

JGLD series of intelligent electromagnetic flowmeter

 

JGLD series of intelligent electromagnetic flowmeter using the latest technology. Using constant frequency three-valued rectangular wave or square wave excitation frequency, both the advantages of square wave magnetic field, but also overcome the shortcomings of sinusoidal magnetic field; also can eliminate the power supply voltage fluctuations, power and excitation frequency caused by changes in coil impedance Error; and have excellent zero stability and noise impact from the fluid. Which has high stability, high reliability characteristics. Intelligent electromagnetic flowmeter measurement principle is based on Faraday's law of electromagnetic induction, intelligent sensors and electromagnetic flowmeter converter formed by a sensor installed in the measuring pipe, the converter can be connected with the sensor combination is called an electromagnetic flow meter body, Converter is installed within 30 meters away from the sensor, or 100 meters of the occasion, shielded cable connection between the two as separate from the electromagnetic flowmeter. Intelligent Electromagnetic Flowmeter main components are: measuring tube, electrode, excitation coil, core and yoke housing. Intelligent electromagnetic flowmeter for measuring the conductivity of closed conduits volume of liquid and slurry flow. Such as water, sewage, slurry, pulp, acids, alkalis, salt solution, slurry and other food products, intelligent electromagnetic flowmeter has been widely used in petroleum, chemical, metallurgical, textile, food, pharmaceutical and paper industry and environmental protection, municipal Management, water conservancy construction and other fields。

Features:
1、Measured from the fluid density, viscosity, temperature, pressure and electrical conductivity change;
2、Unhindered flow measuring tube parts, no pressure drop, straight pipe requirements are lower;
3、Series DNDN15DN3000。Sensors lining and electrode materials have several choices;
4、Exciting new way converter, low power consumption, zero stability, high accuracy. Flow range can reach15001
5、Converter with sensors or separation of a body type;
6、Converter16Bit high-performance microprocessors,2x16LCDDisplay, convenient parameter setting, programming and reliable;
7、Two-way flow measurement system, built three totalizers: forward total, reverse total amount of the total and difference; to display. Chuang, anti-traffic, and has a variety of output: current, pulse, digital communications、HART
8、Converter using surface mount technologySMT,With self-test and self-diagnostic function;

Main technical data:
Machine and sensor technical data

Implementation of standards

JBT 9248~1999

DN

152025324050658010012515020025030035040045050060070080090010001200140016001800200022002400260028003000

The maximum flow rate

15ms

Accuracy

DNl5DN600

Indication of:±0.3% Velocity≥1ms±3mmsVelocity<1ms

DN700~DN3000

Indication of±0.5%Velocity≥0.8mS±4mmsVelocity<0.8mS

Fluid conductivity

≥5uScm

PN

4.0MPa

1.6MPa

1.0MPa

0.6MPa

6.310MPa

DNl5DN150

DNl5DN600

DN200DN1000

DN700DN3000

Special order

Ambient temperature

Sensors

-25℃- +60℃

Converter and a body

-10℃- +60℃

Lining material

PTFE, neoprene, polyurethane, polyethylene FEPF46、ScreeningPFA

The maximum fluid temperature

A body

70℃

Separate

Neoprene lining

80℃120℃When ordering

Polyurethane lining

80℃

PTFE liner

100℃150℃When ordering

Poly FEPF46

ScreeningPFA

Signal electrode and ground electrode material

Stainless steel0Crl8Nil2M02Ti、HastelloyC、HastelloyB、Titanium, tantalum, platinum / iridium alloy, Stainless steel coated with tungsten carbide

Electrode scraper

DN300—DN3000

Flange material

Carbon steel

Grounded flange material

Stainless steel1Crl8Ni9Ti

Import protection flange material

DN65—DNl50

Stainless steel1Crl8Ni9Ti

DN200DNl600

Carbon steel十Stainless steel1Crl8Ni9Ti

Protective shell

DNl5DN3000Separate Rubber or polyurethane lining Sensors

IP65 or IP68

Other Sensors, a flow meter and Separate size converter

IP65

Spacing Separate

Sensors converters generally do not exceed the distance100m

Technical data converters

Power

Communication

85—265V45—400Hz

DC

11—40V

Operation keys and display

Push-button

4 membrane keys all parameters can be set to choose, can also be usedPCRS232The converter set programming;

3LCDWide viewing angle, wide temperature, with a backlit display;

Line shows the flow of value 1;

Line shows the flow of value 2;

Line 3 shows the percentage of traffic, the total positive, negative total margin, alarm, Velocity。

Magnetic button

2A magnetic button used to display the parameter selection and reset,UsePCRS232The converter set programming;

2LCDWide viewing angle, wide temperature, with a backlit display:

1:Magnetic key:Shows the percentage of traffic, the total positive, negative total margin, alarm、Velocity。

2:Display of flow。

Internal totalizer

Total forward, reverse, and the difference between the total amount。

Output signal

One-way analog output

Fully isolated, load≤600D20mA时;

Ceiling:0—21mAOptionally, each filelmA

Lower limit:0—21mAOptionally, each file1mA

Forward and reverse flow output programming。

Two-way analog output

Lower limit Limit. Or4mA,The other with one-way analog output。

Bi-directional pulse output

Two outputs corresponding to forward and reverse flow,Frequency0800Hz,Ceiling1~800HzOptional,Each fileIHz

Square wave or pulse width selected, the selected pulseCeiling25S,Each file1ms

Passive isolation transistor switching output can be absorbed 250mA of current, voltage 35V。

Dual alarm output

Alarm programming can be high / low flow, air traffic control, fault status, positive, reverse flow, analog over-range, pulse volume over range, the pulse small signal removed, the output polarity Optional;

Isolated protection transistor switch output,Absorbable250mACurrent,Pressure35V.With the pulse output is not isolated

Digital communication

 

RS232RS485HART

The choice of lining

Lining material

The main performance

Maximum medium temperature

Scope of application

Body

Separate

 

PTFE(F4

Is the most stable chemical properties of a plastic, the ability of boiling hydrochloric acid, sulfuric acid, nitric acid and aqua regia, and ability to concentrated alkali, and various organic solvents. Intolerant of chlorine trifluoride, chlorine trifluoride high temperature, high Velocity liquid fluorine, liquid oxygen, since oxygen corrosion。

70℃

100℃ 150℃ Special order

1、Concentrated acid, alkali and other strong corrosive medium。 2、Health class medium。

Poly FEP(F46

The sameF4,Wear resistance, negative pressure is higher than thatF4

The same上

 

Co-poly vinyl fluoride(Fs

Ceiling temperature than PTFE for low, but the cost is also low。

80℃

 

Neoprene

1、Has excellent flexibility, high tearing strength, good wear resistance。2、Generally low concentration of acid resistant, alkali and salt corrosion medium, medium oxidation corrosion intolerance。

80℃ 120℃ Special order

Water, sewage, low wear resistance of the mud slurry; 。

Polyurethane rubber

1、Strong wear resistance。

2、Poor corrosion resistance。

80℃

Strong wear neutral slurry, coal slurry, mud

Import protection and grounding flange ring flange or the choice of ground

Flange type

Scope of application

Ground or ground ring flange

For non-conductive pipes, such as plastic piping, but does not require a grounding electrode Sensors。

Import protection flange

When the media has a strong selection of wear and tear of time。

Electrode selection

Electrode materials

Corrosion and wear resistance

Stainless steel0Crl8Nil2M02Ti

For industrial water, domestic water, sewage and other corrosive media with weak, for the petroleum, chemical, steel and other industrial departments and, municipal and environmental protection。

HastelloyB

Boiling point of all of the following concentrations of hydrochloric acid has good corrosion resistance, and resistance to sulfuric acid, phosphoric acid, hydrofluoric acid, organic acids and other non-chloride, acid, alkali, salt solution of non oxidative corrosion。

HastelloyC

Ability of non-oxidizing acid, such as nitric acid, mixed acid, or chromic acid and sulfuric acid corrosion of mixed media, but also salts such as resistance to oxidation:Fe"、、Cu"Or under the corrosion with other oxidants such as hypochlorite solution above room temperature, seawater corrosion

Titanium

Capability of water, a variety of chloride and hypochlorite, oxidizing acids, including fuming sulfuric acid, organic acid and alkali corrosion. Impatient with the reduction of pure acid such as sulfuric acid, hydrochloric acid corrosion, but as with oxidants such as nitric acid、Fc++、Cu++,Greatly reduced the corrosion。

Tantalum

Has excellent corrosion resistance and glass are similar. In addition to hydrofluoric acid, fuming sulfuric acid, alkali, almost all chemical media capability, including boiling hydrochloric acid, nitric acid and l 50 ℃ below the sulfuric acid corrosion. Diao in alkali; corrosion。

Platinum/TitaniumAlloy

Virtually all chemical media capability, but not for aqua regia and ammonium。

Stainless steel Tungsten carbide coating

For non-corrosive, strong wear resistance of the medium。

Note: Due to a wide range of media, the corrosive but also by temperature, concentration, Velocity change and other complex factors, so this table is for reference only. Users should make their own choices based on the actual situation, if necessary, make plans to select the material should be corrosion tests, such as the coupon test。

JGLD series of intelligent flow meter instrument selection

◆Confirmation measuring range

    General industrial use smart media Velocity measured by electromagnetic flowmeter24m/sAppropriate, in exceptional circumstances, shall not be less than the minimum Velocity0.2m/s,Should not be greater than the highest8m/s。If the medium contains solid particles, often Velocity should be less than3m/s,To prevent excessive friction lining and the electrode; for viscous fluid,VelocityOptionalOptional larger2m/s,Larger VelocityHelp to automatically remove the electrode attached to the role of viscous material, helping improve the measurement accuracy。

Q has been determined in the range of conditions, to the scope of the above decision Velocity V meter aperture size D, the value calculated by the following formula:

Q=πD2V/4
Q:
Flow(㎡/h D:Pipe diameter V:Velocity(m/h

The range of intelligent flow meterQShould be larger than the expected maximum flow value, while the normal flow values are slightly larger than the scale of full scale flow meter50Appropriate。

JGLDReference Series Intelligent Electromagnetic Flowmeter flow range

Diametermm

Flow rangem3/h

Diametermm

Flow rangem3/h

φ15

0.06~6.36

φ450

57.235722.65

φ20

0.1111.3

φ500

70.657065.00

φ25

0.1817.66

φ600

101.7410173.6

φ40

0.4545.22

φ700

138.4713847.4

φ50

0.7170.65

φ800

180.8618086.4

φ65

1.19119.4

φ900

228.9122890.6

φ80

1.81180.86

φ1000

406.9440694.4

φ100

2.83282.60

φ1200

553.9055389.6

φ150

6.36635.85

φ1600

723.4672345.6

φ200

11.31130.4

φ1800

915.6291562.4

φ250

17.66176.25.

φ2000

1130.4113040.00

φ300

25.432543.40

φ2200

1367.78136778.4

φ350

34.623461.85

φ2400

1627.78162777.6

φ400

45.224521.6

φ2600

1910.38191037.6

JGLD Series of intelligent electromagnetic flowmeter selection

 

Model

Diameter

 

JGLD

15~2600

 

 

Code

Electrode materials

 

K1

316L

K2

HB

K3

HC

K4

Titanium

K5

Tantalum

K6

PlatinumAlloy

K7

Stainless steelTungsten carbide coating

 

Code

Lining material

 

C1

PTFEF4

C2 Poly FEP F46
C3 Co-poly vinyl fluoride FS
C4 Poly recorded polybutadiene rubber
C5 Polyurethane rubber
  Code Function
E1 0.3
E2
0.5
E3
1
F1 4-20Madc,Load ≤750Ω
F2 0-3khz, 5v active, variable pulse width, output frequency of high-effective
F3 RS485 Interface
T1 Normal temperature
T2
High temperature
T3
Ultra-high temperature
P1 1.0MPa
P2 1.6MPa
P3
4.0MPa
P4
16MPa
D1 220VAC±10%
D2 24VDC±10%
J1 A body structure
J2 Sub-body structure
J3 Proof of a body structure

All rights reserved:Jiangsu Golden Delicious Control Technology Co., Ltd.,        Tel:0517-86867887 0517-86803168     Tex:0517-86891587
Temperature Instrumentation Division     Pressure Instrumentation Division         Calibration instruments Division
Flow meter Division     Display Instrument Division     Instrument Division transmitter      Wire and Cable Business Unit