ÖÐÎÄ°æ English
          Home©¦  Company©¦  Product©¦  Quality©¦  Sales©¦  Contact
 
 Flow meter series
 Transmitter meter...
 Pressure Meter Series
 Temperature meter...
 Check meter series
 Display Instrument...
 Wire and cable series
 Electric heating series
 
  The working principle of...
  Zirconia Oxygen Sensor...
  Hazardous gas detection...
  Our instrument for...
  China Hi-tech instrumentation.
  Development of Xi'an ...
  Precision temperature...
  The development trend of ...
  Description of several gas...
  Use of sensor technology...
  New sensors monitor the...
 
  Jiangsu Golden Delicious Control Technology Co., Ltd.,
  TEL£º0517-86867887
     0517-86867888
     0517-86867889
  FAX£º0517-86891587
Join Hotline£º0517-86803168
              13905232000
  Technical Support£º0517-86886468
  Zip:211600
  Address:Jiangsu Province, Lake County gongyuan Road, No. 1
 You are Here > Home > Product
     

JGLD electromagnetic flowmeter

 

JGLD electromagnetic flowmeter

Outline:
????The SKLD series electromagnetic flowmeter survey principle is the Faraday law of electromagnetic induction, the sensor key component is: Measuring tube, electrode, exciting coil, ferrite core and magnetic yoke shell. It mainly uses in surveying in solid surrounding boundary's electric conduction liquid and the size rate of volume flow. Including acid, alkali, salt and so on strong corrosive liquid. This product widely applies in professions as well as the environmental protection, the municipal administration management and so on petroleum, chemical industry, metallurgy, spinning and weaving, food, drugs manufacture, papermaking, domains and so on water conservancy facility.

Product characteristic:
1st, survey not fluid density, viscosity, temperature, pressure and conductivity change influence;
2nd, in the measuring tube the free from obstacle flowing part, does not have the damaged due to pressing, the straight length of pipe request is low;
3rd, series nominal size DN15~DN3000. The sensor lining and the electrode material has the multiple options;
4th, the switch selects the novel excitation method, the power loss is low, zero stable, the precision is high. The current capacity scope may reach 1500:1;
5th, the switch may compose a build with the sensor or the separation;
6th, the switch uses 16 high performance microprocessors, 2x16LCD demonstrated that the parameter hypothesis is convenient, the programming is reliable;
7th, flowmeter for bidirectional measurement system, internal installation three integrators: Forward total quantity, reverse total quantity and differential value total quantity; May demonstrate. The village, the counter-current capacity, and have many kinds of outputs: Electricity
??? Class, pulse, digital communication, HART;
8th, the switch uses surface mounting technical (SMT), has self-checking and from the diagnosis function;

Main technicaldata:
Complete machine and sensor engineering data

Carries out the standard

JB/T 9248-1999

Nominal size

15th, 20, 25, 32, 40, 50, 65, 80, 100, 125, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1200, 1400, 1600, 1800, 2000, 2200, 2400, 2600, 2800, 3000

Most high flow rate

15m/s

Precision

DNl5~DN600

Shows the value: ¡À0.3% (speed of flow ¡Ý1m/s); ¡À3mm/s (speed of flow <1m/s)

DN700-DN3000

Shows the value ¡À0.5% (speed of flow ¡Ý0.8m/S); ¡À4mm/s (speed of flow <0.8m/S)

Fluid conductivity

¡Ý5uS/cm

Nominal pressure

4.0MPa

1.6MPa

1.0MPa

0.6MPa

6.3rd, 10MPa

DNl5~DN150

DNl5~DN600

DN200~DN1000

DN700~DN3000

Special orders

Ambient temperature

Sensor

- 25 ¡æ - 70 ¡æ

Switch and a build

- 10 ¡æ - 70 ¡æ

Lining material

The teflon, gathers the chloroprene rubber, the polyurethane, to gather the entire fluorine second grade propylene (F46), to add net PFA

Highest fluid temperature

- build

70¡æ

Separation

Gathers the chloroprene rubber lining

80¡æ; 120¡æ (when ordering indication)

Polyurethane lining

80¡æ

Teflon lining

100¡æ; 150¡æ (when ordering indication)

Gathers the entire fluorine second grade propylene (F46)

Adds net PFA

Signal electrode and earth electrode material

Stainless steel 0Crl8Nil2M02Ti, alloy C, alloy B, titanium, tantalum, platinum/iridium alloy, stainless steel spreading tungsten carbide

Electrode shaving knife organization

DN300-DN3000

Attachment flange material

Carbon steel

Earth flange material

Stainless steel 1Crl8Ni9Ti

Import protection flange material

DN65-DNl50

Stainless steel 1Crl8Ni9Ti

DN200~DNl600

Carbon steel ten stainless steel 1Crl8Ni9Ti

Outer covering protection

DNl5~DN3000 separation rubber or polyurethane lining sensor

IP65 or IP68

Other sensors, - - build flowmeter and separation switch

IP65

Spacing (separation)

The switch range sensor does not surpass 100m generally


Switch engineering data

Power source

Exchange

85-265V,45-400Hz

Cocurrent

11-40V

Operates the key and the demonstration

Presses a key the type

4 thin film pressed keys may establish choose the complete parameter, may also use the PC machine (RS232) pair of switch hypothesis programming;

3 line of LCD wide angles of view, the width are warm, belt back light demonstration;

1st line of demonstration flow rate;

2nd line of demonstration Flux unit;

3rd line of demonstration current capacity percentage, to total quantity, reverse total quantity, differential value total quantity, warning, speed of flow.

Magnetism key type

2 magnetism keys use in demonstrating that the parameter the choice and the replacement, use the PC machine (RS232) pair of switch hypothesis programming;

2 line of LCD wide angles of view, the width are warm, the belt back light demonstrated:

The 1st line: Magnetism key choice: Demonstrates the current capacity percentage, to the total quantity, the reverse total quantity, the differential value total quantity, the warning, the speed of flow.

The 2nd line: Demonstrates the current capacity.

Internal integrator

Forward total quantity, reverse total quantity and differential value total quantity.

Output signal

Unidirectional analog output

Entire isolation, load ¡Ü600D. (when 20mA);

Upper limit: 0-21mA may elect, each grade of lmA;

Lower limit: 0-21mA may elect, each grade of 1mA;

Forward and reverse current capacity output mode programming.

Bidirectional analog output

The lower limit limit is. Or 4mA, other with unidirectional analog output.

Double-sided pulse output

Two group output distinction correspondence forward and the reverse current capacity, frequency 0~800Hz, upper limit 1-800Hz may elect, each grade of IHz;

Square-wave or designation pulse width, designation pulse width upper limit 2.5S, each grade of 1ms;

The passive isolation transistor switched output, may absorb 250mA the electric current, pressure resistance 35V.

Two-circuit warning output

May report to the police (programming) the high/low current capacity, the blank pipe, the malfunction, positive, the reverse current capacity, the simulation quantity ultra measuring range, the pulse quantity ultra measuring range, the pulse small signal excision, the output polarity may elect;

The belt isolation protection's transistor switched output, may absorb 250mA the electric current, pressure resistance 35V. (and pulse output isolation)

Digital communication

¡¡

RS232, RS485, HART


Lining's choice

Lining material

Main performance

Highest medium temperature

Applicable scope

- build

Separation

¡¡

Teflon (F4)

Is the chemical properties stablest one kind of plastic, the ability ebullition hydrochloric acid, the sulfuric acid, the nitric acid and the aqua regia, also ability thick alkali and each organic solvent. Does not bear the boron trifluoride chlorine, the high temperature boron trifluoride chlorine, the high flow rate liquid fluorine, the liquid oxygen, from the oxygen corrosion.

70¡æ

100¡æ 150¡æ (needs special orders)

1st, concentrated acid, alkali and so on strong corrosive medium. 2nd, health class medium.

Gathers the entire fluorine second grade propylene (F46)

With F4, the resistance to wear, anti-negative pressure ability are higher than F4.

With on

¡¡

Gathers the fluorine to gather the ethylene (Fs)

Is suitable the temperature upper limit to compare the teflon to be low, but the cost is also low.

80¡æ

¡¡

Gathers the chloroprene rubber

1st, has the extremely good elasticity, the altitude breaking tenacity, the wear-resisting performance is good. 2nd, bears the general low concentration acid, the alkali, the salty medium corrosion, does not bear the oxidized medium the corrosion.

80¡æ 120¡æ (needs special orders)

Water, sewage, weak wearability mud pulp.

Polyurethane rubber

1st, the wear-resisting performance is greatly strengthened.

2nd, the anti-corrosive performance is bad.

80¡æ

Neutral strong attrition pulp, coal tar, mud


Import protection flange and earth flange (or earth link) choice

Flange type

Applicable scope

Earth flange (or earth link)

Is suitable in the non-conductor pipeline, if plastic pipeline, but has earth electrode's sensor not to need.

Import protection flange

When the medium has the strong wearability selects.


Electrode's choice

Electrode material

Anticorrosion and wear-resisting performance

Stainless steel 0Crl8Nil2M02Ti

Uses in the process water, the domestic water, the sewage and so on having the pickling medium, is suitable in Industry sectors and so on petroleum, chemical industry, steel and iron and, domains and so on municipal administration, environmental protection.

Alloy B

Has the good corrosion resistance to below the boiling point all density's hydrochloric acid, also bears the sulfuric acid, the phosphoric acid, the hydrofluoric acid, the organic acid and so on non-chlorination acid, the alkali, non-oxidized salty fluid corrosion.

Alloy C

Ability non-oxidized acid, like nitric acid, nitration mixture, or chromic acid and sulfuric acid mix medium corrosion, also bears the oxidized salt as for example: Fe,¡±, Cu¡± under or including other oxidant's corrosion, like is higher than the normal temperature the hypochlorous acid salt brine, the sea water corrosion

Titanium

Ability sea water, each kind of chloride and hypochlorite, oxidized acid (including fuming sulfuric acid), organic acid, alkali corrosion. Does not bear the pure reducible acid (for example sulfuric acid, hydrochloric acid) corrosion, but like in the acid includes the oxidant (for example nitric acid, Fc++, Cu++) time, then corrodes to reduce greatly.

Tantalum

Has the fine corrosion resistance and the glass is very similar. Besides the hydrofluoric acid, the fuming sulfuric acid, the alkali, the ability - - cuts the chemical mediator nearly (including boiling point hydrochloric acid, nitric acid and the l 50¡æ following sulfuric acid) the corrosion. In alkali tricky; Anticorrosion.

Platinum/titanium alloy

The ability - - cuts the chemical mediator nearly, but is not suitable for the aqua regia and the ammonium salt.

Stainless steel spreading tungsten carbide

Uses in non-corrosiveness, strong wearability medium.

Note: As a result of the medium great variety, its corrosiveness receives the temperature, the density, the speed of flow and so on complex factor influence to change, therefore this table only supplies the reference. The user should act according to actual situation make the choice, when the necessity should do plans to choose the material the anticorrosive experiment, like lacing film experiment.


SKLD series electromagnetic flowmeter measuring appliance shaping
¡ô measuring range scope confirmation
Generally the industrial used electromagnetic flowmeter was measured that the medium speed of flow take 2~4m/s as suitable, in the peculiar circumstance, the lowest speed of flow should not be smaller than 0.2m/s, highest should not be bigger than 8m/s. If in the medium includes the solid particle, the commonly used speed of flow should be smaller than 3m/s, prevents the lining and electrode's excessive friction; Regarding the viscous fluid, the speed of flow may choose is bigger than 2m/s, the great speed of flow is helpful to eliminates sluggish which automatically on the electrode adheres to stick cohere the function, is advantageous in the enhancement measuring accuracy.
In measuring range Q had determined under the condition, then acts according to above speed of flow V scope decision flowmeter caliber D the size, its value calculates based on the equation below:
Q=¦ÐD2V/4
Q: Current capacity (©O/h) D: Pipeline inside diameter V: Speed of flow (m/h)
Electromagnetic flowmeter's measuring range Q should be bigger than the estimate the maximal-flow size, but the normal flow rate take is bigger than the flowmeter full scale scale division suitably slightly 50 as.
¡ôSKLD series electromagnetic flowmeter reference current capacity scope

Caliber mm

Current capacity scope m3/h

Caliber mm

Current capacity scope m3/h

¦Õ15

0.06~6.36

¦Õ450

57.23~5722.65

¦Õ20

0.11~11.3

¦Õ500

70.65~7065.00

¦Õ25

0.18~17.66

¦Õ600

101.74~10173.6

¦Õ40

0.45~45.22

¦Õ700

138.47~13847.4

¦Õ50

0.71~70.65

¦Õ800

180.86~18086.4

¦Õ65

1.19~119.4

¦Õ900

228.91~22890.6

¦Õ80

1.81~180.86

¦Õ1000

406.94~40694.4

¦Õ100

2.83~282.60

¦Õ1200

553.90~55389.6

¦Õ150

6.36~635.85

¦Õ1600

723.46~72345.6

¦Õ200

11.3~1130.4

¦Õ1800

915.62~91562.4

¦Õ250

17.66~176.25.

¦Õ2000

1130.4~113040.00

¦Õ300

25.43~2543.40

¦Õ2200

1367.78~136778.4

¦Õ350

34.62~3461.85

¦Õ2400

1627.78~162777.6

¦Õ400

45.22~4521.6

¦Õ2600

1910.38~191037.6

The SKLDE series intelligence electromagnetic flowmeter chooses the spectrum

Model

Caliber

?

SKLD

15~2600

?

?

Code number

Installs the form

?

Y

Integration

F

Fission type

?

Code number

Switch model

ZA

Circular

ZB

Square shape

?

Code number

Output signal

I.4

4~20mA

f

Frequency 1KHz

Rs

Serial communication (485)

C

Control output

?

?Code number

Explosion-proof request

?N

Does not have the explosion-proof

EX

The explosion-proof (is only suitable for fission type)

?

Code number

Medium temperature

T1

¡Ü65¡æ

T2

¡Ü65¡æ

T3

¡Ü180¡æ (is only suitable for fission type)

?

Code number

Inside lining material quality

NE

Chloroprene rubber (¡Ü65¡æ)

PTFE

Teflon (¡Ü189¡æ)

PVC

Polyvinyl-chloride (¡Ü70¡æ)

?

Code number

Electrode material quality

316L

Stainless steel

HC

Alloy C

HB

Alloy B

Ti

Titanium

Ta

Tantalum

The serial products includes: The integration electromagnetic flowmeter, the fission type electromagnetic flowmeter, the jack-in type electromagnetic flowmeter, the anti-corrosive electromagnetic flowmeter, brings the communication electromagnetic flowmeter

All rights reserved£ºJiangsu Golden Delicious Control Technology Co., Ltd.,        Tel:0517-86867887 0517-86803168     Tex:0517-86891587
Temperature Instrumentation Division     Pressure Instrumentation Division         Calibration instruments Division
Flow meter Division     Display Instrument Division     Instrument Division transmitter      Wire and Cable Business Unit