一、Scope of application
Fluoroplastic wire temperature compensation, compensation cable has better high temperature performance, long between -40 ℃ -200 ℃ compared with corrosive gases such as poor working conditions. And have acid, oil and resistance to aging, and can be an effective instrument to ensure that the connection between the thermocouple and and transmit signals. Fluoroplastic wire temperature compensation is now widely used in electric power, metallurgy, oil, temperature and chemical fields。
二、Implementation of standards
GB/T4989-94
三、Model
Fluoroplastic wire temperature compensation by species classified as SC, KC, BC, NC, KX, EX, JX, and WC3/25, WC5/26 etc /. Where the letter "C" that the compensation-type "X" that extended type。
Equipped with a thermocouple |
Dividing number |
Compensation wireModel |
Insulation and sheath materials |
Temperature range |
Ni-Cr - Ni Si |
K |
KX-HFF
KC-HFF
KC-HFFP
KX-HFFRP
KC-HFHFFRP |
F46 |
-40℃至200℃ |
Platinum Rhodium 10 - Platinum |
S |
SC-HFF
SC-HFFP
SC-HFFRP |
F46 |
Nickel-chromium - constantan |
E |
EX-HFF
EX-HFFP
EX-HFFRP |
F46 |
Iron - constantan |
J |
JX-HFF
JX-HFFP
JX-HFFRP |
F46 |
Iron - constantan |
T |
TX-HFF
TX-HFFP
TX-HFFRP |
F46 |
四、Ordering Information
Order to be labeled Model, specifications, core cross-section, core number, and number of screening methods
|