中文版 English
          Home  Company  Product  Quality  Sales  Contact
 
 Flow meter series
 Transmitter meter...
 Pressure Meter Series
 Temperature meter...
 Check meter series
 Display Instrument...
 Wire and cable series
 Electric heating series
 
  The working principle of...
  Zirconia Oxygen Sensor...
  Hazardous gas detection...
  Our instrument for...
  China Hi-tech instrumentation.
  Development of Xi'an ...
  Precision temperature...
  The development trend of ...
  Description of several gas...
  Use of sensor technology...
  New sensors monitor the...
 
  Jiangsu Golden Delicious Control Technology Co., Ltd.,
  TEL:0517-86867887
     0517-86867888
     0517-86867889
  FAX:0517-86891587
Join Hotline:0517-86803168
              13905232000
  Technical Support:0517-86886468
  Zip:211600
  Address:Jiangsu Province, Lake County gongyuan Road, No. 1
 You are Here > Home > Product
     

Thermocouple compensating cables, compensation cables

Compensation for thermocouple extension wire is used to heat the electrode that is moving the thermocouple cold junction, and display temperature meter connection constitutes a system. This product uses the GB / T 4989-94 "thermocouple compensating cables, " the national standard (equivalent with IEC584-3 "Thermocouple Part III - compensation wire"international standard), insulation layer And fluorine sheath imported high quality plastic, and the overall continuous extrusion using new technology, so that the product has good acid and alkali, wear resistance and extend the performance of non-combustible, can be immersed in water long-term use. Temperature -60-205-260 ℃, is the contemporary international advanced level. Products are mainly used in various temperature measurement devices, has been widely used in petroleum, chemical, metallurgy, electric power sector。
型号表示


The main technical indicators:
Compensation wire models into species by productSC、KC、KX、EX、JX、TX、NC
Of which: a) Type the first letter with the thermocouple corresponding to the sub-degree numbers;
b) the letter "X" said Extended compensation wire (type);
c) the letter "C" that the compensation-based compensation wire (type)。
Note: SC-based compensation wire can be equipped with R-type thermocouple dividing number

Structure, the insulating layer, protecting layer materials, the use of temperature Use classification, tolerance level, sheath color logo
Insulating layer and the protection layer Temperature
Material Symbol
Polyvinyl fluoride PVC -25~70℃
-25~105℃
Poly FEP FEP -60~205℃
Soluble PTFE PFA -60~260℃
Results must indicate
Sheath Insulation Alloy wire Sheath Shield Alloy wire
Use classification Signs Sheath allows registration and coloring
General level Precision
General use G (Black) S(Gray)
Heat use H (Black) S(Gray)


Product label (tag) Alloy wire and the compensation wire insulation color
Equipped with a thermoelectric
Even dividing number
General use(G)
Product labeling
Heat use(H)
Product labeling
General level Precision(S) General level Precision(S)
S SC-G SC-GS SC-H --
N NC-G NC-GS NC-H NC-HS
K NC-G NC-GS NC-H --
KC2-G KG2-GS KC2-H KC2-HS
KX-G KX-GS KX-H KX-HS
E EX-G EX-GS EX-H EX-HS
J JX-G JX-GS JX-H JX-HS
T TX-G TX-GS TX-H TX-HS
No compensation
Line model
Equipped with a thermoelectric
No. Even the sub-degree
Compensation wire alloy wire Insulation
Coloring
Positive Negative Positive Negative
SC S(Chrome Platinum 10 - Platinum) SPC(Copper) SNC(Copper and nickel) Red Green
NC N(Ni-Cr-Si - Ni Si) NPC(Iron) NNC(Copper and nickel) Red Yellow
KC K(Copper - constantan) KPC(Copper) KNC(Copper and nickel) Red Blue
KX K(c) KPX(Nickel chrome) KNX(Copper and nickel) Red Black
EX E(Nickel chrome—Copper and nickel) EPX(Nickel chrome) ENX(Copper and nickel) Red Brown
JX J(Iron—Copper and nickel) JPX(Iron) JNX(Copper and nickel) Red Purple
TX T(Copper—Copper and nickel) TPX(Copper) TNX(Copper and nickel) Red White

Compensation wire thermoelectric power, tolerance
  Thermoelectric power and tolerance(μV) Thermocouple testing
End temperature(℃)
100 ℃
100 ℃
Thermoelectric power
(Standard value)
Yun-poor Thermoelectric power
(Standard value)
Yun-poor
General level Precision(S) General level Precision(S)
SC or RC 645 ±60(±5.0℃) ±30(±2.5℃) 1440 ±60(±5.0℃) -- 1000
KCA 4095 ±100(±2.5℃) ±60(±1.5℃) 8137 ±100(±2.5℃) ±60(±1.5℃) 900
KCB 4095 ±100(±2.5℃) ±60(±1.5℃) 8137 -- -- 900
KX 4095 ±100(±2.5℃) ±60(±1.5℃) 8137 ±100(±2.5℃) ±60(±1.5℃) 900
NC 2774 ±100(±2.5℃) ±60(±1.5℃) 5912 ±100(±2.5℃) ±60(±1.5℃) 900
NX 2774 ±200(±2.5℃) ±60(±1.5℃) 5912 ±100(±2.5℃) ±60(±1.5℃) 900
EX 6317 ±60(±2.5℃) ±120(±1.5℃) 13419 ±200(±2.5℃) ±120(±1.5℃) 600
JX 5268 ±140(±2.5℃) ±85(±1.5℃) 10777 ±140(±2.5℃) ±85(±1.5℃) 500
TX 4277 ±60(±1.0℃) ±30(±0.5℃) 9285 ±90(±1.5℃) ±48(±0.8℃) 300


Compensation wire line core section, the number of shares, in-line diameter and insulation, Sheath and outer diameter size:
Use classification Nominal cross section(mm2) Single strand wire core Multi-strand flexible wire core(R) Insulating layer thickness(mm)

SheathThickness

(mm)

Maximum diameter(mm)

Cores shares

(Root)

Single diameter

(mm)

Cores

shares

(Root)

Single diameter

(mm)

Flat Flat screen
Single strand wire core Multi-strand wire core Single strand wire core Multi-strand wire core
General use(G) 0.2 1 0.5 7 0.2 0.4 0.7 3.0x4.6 3.1x4.8 3.8x5.4 3.9x5.6
0.5 1 0.80 7 0.30 0.5 0.8 3.7x6.4 3.9x6.6 4.5x7.2 4.7x7.4
1.0 1 1.13 7 0.43 0.7 1.0 5.0x7.7 5.1x8.0 5.8x8.5 5.9x8.8
1.5 1 1.37 7 0.52 0.7 1.0 5.2x8.3 5.5x8.7 6.0x9.1 6.3x9.6
2.5 1 1.76 19 0.41 0.7 1.0 5.7x9.3 5.9x9.8 6.5x10.1 6.7x10.7
Heat use(H) 0.2 1 0.5 7 0.2 0.4 0.3 2.3x4.0 2.4x4.2 3.1x4.8 3.2x5.0
0.5 1 0.80 7 0.3 0.4 0.3 2.9x5.0 3.0x5.2 3.7x5.5 3.8x6.0
1.0 1 1.13 7 0.43 0.4 0.3 3.5x5.7 3.7x6.1 4.3x6.5 4.5x6.9
1.5 1 1.37 7 0.52 0.4 0.3 4.0x6.5 4.2x6.9 4.8x7.3 5.0x7.7
2.5 1 1.76 19 0.41 0.4 0.3 4.5x7.3 4.8x7.9 5.3x8.1 5.6x8.7

Provide delivery instructions:
1, 100m or the entire length of delivery times, allowing a short section of not less than 20m of cable delivery, but the number may not exceed 10% of the total delivery。
2, thermocouple compensating cable factory production for the use of multi-point temperature。
3, the user any special needs, can be in the order specified in the contract。
All rights reserved:Jiangsu Golden Delicious Control Technology Co., Ltd.,        Tel:0517-86867887 0517-86803168     Tex:0517-86891587
Temperature Instrumentation Division     Pressure Instrumentation Division         Calibration instruments Division
Flow meter Division     Display Instrument Division     Instrument Division transmitter      Wire and Cable Business Unit