Thermocouple compensating cables, compensation cables
|
Compensation for thermocouple extension wire is used to heat the electrode that is moving the thermocouple cold junction, and display temperature meter connection constitutes a system. This product uses the GB / T 4989-94 strong> "thermocouple compensating cables, " the national standard (equivalent with IEC584-3 "Thermocouple Part III - compensation wire"international standard), insulation layer And fluorine sheath imported high quality plastic, and the overall continuous extrusion using new technology, so that the product has good acid and alkali, wear resistance and extend the performance of non-combustible, can be immersed in water long-term use. Temperature -60-205-260 ℃, is the contemporary international advanced level. Products are mainly used in various temperature measurement devices, has been widely used in petroleum, chemical, metallurgy, electric power sector。
型号表示
The main technical indicators:
Compensation wire models into species by productSC、KC、KX、EX、JX、TX、NC
Of which: a) Type the first letter with the thermocouple corresponding to the sub-degree numbers;
b) the letter "X" said Extended compensation wire (type);
c) the letter "C" that the compensation-based compensation wire (type)。
Note: SC-based compensation wire can be equipped with R-type thermocouple dividing number
Structure, the insulating layer, protecting layer materials, the use of temperature |
Use classification, tolerance level, sheath color logo |
Insulating layer and the protection layer |
Temperature |
Material |
Symbol |
Polyvinyl fluoride |
PVC |
-25~70℃
-25~105℃ |
Poly FEP |
FEP |
-60~205℃ |
Soluble PTFE |
PFA |
-60~260℃ |
Results must indicate |
Sheath |
Insulation |
Alloy wire |
Sheath |
Shield |
Alloy wire |
|
|
|
Use classification |
Signs |
Sheath allows registration and coloring |
General level |
Precision |
General use |
G |
(Black) |
S(Gray) |
Heat use |
H |
(Black) |
S(Gray) |
|
Product label (tag) |
Alloy wire and the compensation wire insulation color |
Equipped with a thermoelectric
Even dividing number |
General use(G)
Product labeling |
Heat use(H)
Product labeling |
General level |
Precision(S) |
General level |
Precision(S) |
S |
SC-G |
SC-GS |
SC-H |
-- |
N |
NC-G |
NC-GS |
NC-H |
NC-HS |
K |
NC-G |
NC-GS |
NC-H |
-- |
KC2-G |
KG2-GS |
KC2-H |
KC2-HS |
KX-G |
KX-GS |
KX-H |
KX-HS |
E |
EX-G |
EX-GS |
EX-H |
EX-HS |
J |
JX-G |
JX-GS |
JX-H |
JX-HS |
T |
TX-G |
TX-GS |
TX-H |
TX-HS |
|
No compensation
Line model |
Equipped with a thermoelectric
No. Even the sub-degree |
Compensation wire alloy wire |
Insulation
Coloring |
Positive |
Negative |
Positive |
Negative |
SC |
S(Chrome Platinum 10 - Platinum) |
SPC(Copper) |
SNC(Copper and nickel) |
Red |
Green |
NC |
N(Ni-Cr-Si - Ni Si) |
NPC(Iron) |
NNC(Copper and nickel) |
Red |
Yellow |
KC |
K(Copper - constantan) |
KPC(Copper) |
KNC(Copper and nickel) |
Red |
Blue |
KX |
K(c) |
KPX(Nickel chrome) |
KNX(Copper and nickel) |
Red |
Black |
EX |
E(Nickel chrome—Copper and nickel) |
EPX(Nickel chrome) |
ENX(Copper and nickel) |
Red |
Brown |
JX |
J(Iron—Copper and nickel) |
JPX(Iron) |
JNX(Copper and nickel) |
Red |
Purple |
TX |
T(Copper—Copper and nickel) |
TPX(Copper) |
TNX(Copper and nickel) |
Red |
White |
|
Compensation wire thermoelectric power, tolerance
|
Thermoelectric power and tolerance(μV) |
Thermocouple testing
End temperature(℃) |
100 ℃
|
100 ℃ |
Thermoelectric power
(Standard value) |
Yun-poor |
Thermoelectric power
(Standard value) |
Yun-poor |
General level |
Precision(S) |
General level |
Precision(S) |
SC or RC |
645 |
±60(±5.0℃) |
±30(±2.5℃) |
1440 |
±60(±5.0℃) |
-- |
1000 |
KCA |
4095 |
±100(±2.5℃) |
±60(±1.5℃) |
8137 |
±100(±2.5℃) |
±60(±1.5℃) |
900 |
KCB |
4095 |
±100(±2.5℃) |
±60(±1.5℃) |
8137 |
-- |
-- |
900 |
KX |
4095 |
±100(±2.5℃) |
±60(±1.5℃) |
8137 |
±100(±2.5℃) |
±60(±1.5℃) |
900 |
NC |
2774 |
±100(±2.5℃) |
±60(±1.5℃) |
5912 |
±100(±2.5℃) |
±60(±1.5℃) |
900 |
NX |
2774 |
±200(±2.5℃) |
±60(±1.5℃) |
5912 |
±100(±2.5℃) |
±60(±1.5℃) |
900 |
EX |
6317 |
±60(±2.5℃) |
±120(±1.5℃) |
13419 |
±200(±2.5℃) |
±120(±1.5℃) |
600 |
JX |
5268 |
±140(±2.5℃) |
±85(±1.5℃) |
10777 |
±140(±2.5℃) |
±85(±1.5℃) |
500 |
TX |
4277 |
±60(±1.0℃) |
±30(±0.5℃) |
9285 |
±90(±1.5℃) |
±48(±0.8℃) |
300 |
Compensation wire line core section, the number of shares, in-line diameter and insulation, Sheath and outer diameter size:
Use classification |
Nominal cross section(mm2) |
Single strand wire core |
Multi-strand flexible wire core(R) |
Insulating layer thickness(mm) |
SheathThickness
(mm) |
Maximum diameter(mm) |
Cores shares
(Root) |
Single diameter
(mm) |
Cores
shares
(Root) |
Single diameter
(mm) |
Flat |
Flat screen |
Single strand wire core |
Multi-strand wire core |
Single strand wire core |
Multi-strand wire core |
General use(G) |
0.2 |
1 |
0.5 |
7 |
0.2 |
0.4 |
0.7 |
3.0x4.6 |
3.1x4.8 |
3.8x5.4 |
3.9x5.6 |
0.5 |
1 |
0.80 |
7 |
0.30 |
0.5 |
0.8 |
3.7x6.4 |
3.9x6.6 |
4.5x7.2 |
4.7x7.4 |
1.0 |
1 |
1.13 |
7 |
0.43 |
0.7 |
1.0 |
5.0x7.7 |
5.1x8.0 |
5.8x8.5 |
5.9x8.8 |
1.5 |
1 |
1.37 |
7 |
0.52 |
0.7 |
1.0 |
5.2x8.3 |
5.5x8.7 |
6.0x9.1 |
6.3x9.6 |
2.5 |
1 |
1.76 |
19 |
0.41 |
0.7 |
1.0 |
5.7x9.3 |
5.9x9.8 |
6.5x10.1 |
6.7x10.7 |
Heat use(H) |
0.2 |
1 |
0.5 |
7 |
0.2 |
0.4 |
0.3 |
2.3x4.0 |
2.4x4.2 |
3.1x4.8 |
3.2x5.0 |
0.5 |
1 |
0.80 |
7 |
0.3 |
0.4 |
0.3 |
2.9x5.0 |
3.0x5.2 |
3.7x5.5 |
3.8x6.0 |
1.0 |
1 |
1.13 |
7 |
0.43 |
0.4 |
0.3 |
3.5x5.7 |
3.7x6.1 |
4.3x6.5 |
4.5x6.9 |
1.5 |
1 |
1.37 |
7 |
0.52 |
0.4 |
0.3 |
4.0x6.5 |
4.2x6.9 |
4.8x7.3 |
5.0x7.7 |
2.5 |
1 |
1.76 |
19 |
0.41 |
0.4 |
0.3 |
4.5x7.3 |
4.8x7.9 |
5.3x8.1 |
5.6x8.7 |
Provide delivery instructions:
1, 100m or the entire length of delivery times, allowing a short section of not less than 20m of cable delivery, but the number may not exceed 10% of the total delivery。
2, thermocouple compensating cable factory production for the use of multi-point temperature。
3, the user any special needs, can be in the order specified in the contract。 |
|